Sounding Bob Type Level Meter KSL Series
Sounding bob type level meter has a robust housing and
performs an excellent durability under severe ambient conditions.
It is applicable to various processes.
Features
- With a simple mechanical detection system, it provides stable indications regardless of material in the tank and ambient conditions.
- Internal CPU enables direct pulse/analog output from the sensing unit.(KSL-T8, KSL-MT)
- A trouble alarm contact available as standard. (KSL-T8, KSL-MT)
- Many different check modes, including internal CPU self check mode are available.
- No external space for timer is needed as sensing parts contains auto measuing timer inside.
Operating Principles
When a start signal is input, the motor is activated and
the measuring tape is winded off to lower the weight.
Accordingly, pulses are transmitted at regular intervals.
Once the weight touches the surface of the material in the tank, the motor stops and the measurement value on the level meter is output. Then, the motor winds up the measuring tape to return to the original position.
the measuring tape is winded off to lower the weight.
Accordingly, pulses are transmitted at regular intervals.
Once the weight touches the surface of the material in the tank, the motor stops and the measurement value on the level meter is output. Then, the motor winds up the measuring tape to return to the original position.
Model | KSL-T8 | KSL-T2 |
Power supply | 100VAC or 200VAC, Single-phase 50/60Hz | 100VAC or 200VAC, Single-phase 50/60Hz |
Power consumption | Max.150VA | Max.150VA |
Temperature | Ambient : -10℃~+50℃ Inside tank : -10℃~+80℃ (No freezing/condensation) | Ambient : -10℃~+50℃ Inside tank : -10℃~+80℃ (No freezing/condensation) |
Measurement span | Standard 20m (Option 40m) | Standard 20m (Option 40m) |
Measurement method | Pulse Counting | Pulse Counting |
Measurement unit | 1 pulse/10cm or 1 pulse/1cm | 1 pulse/10cm |
Accuracy | ±1cm / ±10cm | ±10cm |
Motor | Single-phase, Reversible,
Output 40W 30 minutes rating, with brake | Single-phase, Reversible,
Output 40W 30 minutes rating, with brake |
Body material | AC | SPC |
Process connection | JIS 5K125A | JIS 10K100A |
Enclosure rating | IP67 | Equivalent to IP33 |
Output signal | Current signal
DC4~20mA(indicate remains) DC20~4mA(indicate vacated portion) *User can set up either one Pulse contact signal 1 pulse / 1cm (No-volt signal), 1pulse / 10cm *User can set up either one | Possible to control 4-20mA output by combining an optional control unit and P / I converter. |
Output contact | Reset Contact/
for Remote Indication Counter,
ON at the time of reset
Failure Alarm Contact/
Flickers when the measuring
tape is cut off. The contact is closed when the weight is buried. | Possible to control both upper and lower output by combining an optional control unit and P / I converter. |