Leak Type Level Switch KEL-2

No moving part.
Most suitable for detecting sand, aggregate, lime, etc.

Catalog Download

Features

  • Applicable to almost all materials such as construction aggregates, gravels, and crushed stones, as long as they contain moisture.
  • Easy sensitivity setting.
  • Easy installation and handling. No difficult technique is required.
  • As the current that flows measured substances is several dozen μA, any heat and sparks are not produced from the electrode, which ensures the safe operation.

Operating Principles

During the material which contains moisture touches the electrode, when the resistance between the electrode and the metal tank wall is reduced, the change of the resistance is detected and it outputs contact. When there is no material, the output contact is restored to the initial state.
ModelKEL-2
Power Source105/210VAC ±10% 50/60Hz
Output ContactSPDT x 1
Contact CapacityAC250V 5A, DC30V 5A
Temperature0~+50℃(No Condensation or Freez required)
Detecting SensitivityMax. about 10MΩ – Min. about 30kΩ
Sensitivity Setting16 Steps adjustable
Indication LampLights up when detected
Weight3.5kg

Product Lineup

In addition to the above, various specifications are available.
For more information, see respective catalogs or contact us by phone or mail.

  • KEL-2

    Insulator & Electrobe-holding & amplifier

    KEL-2

    Insulator & Electrobe-holding & amplifier

    • Applicable to any site if the material (sand for building material, gravel, crushed stones etc.) contains moisture.
    • Standard model does not include detection probe. We provide it as option.
    • Easy sensitivity setting by turning the dial.