Products

  1. Top
  2. Products
  3. Dust Monitor
  4. VIEW370/LeakAlert/VIEW Ex800

Product Detail

Electrodynamic Dust Monitor VIEW370/LeakAlert/VIEW Ex800

Features

Compared with general friction charge methods and the conventional optical detection method, this dust monitor has a high resolution and stability without being easily affected by adhesion of dust to the probe.

  • It is rarely affected by adhesion and contamination on the probe.
  • Extremely high sensitivity of 0.01 to 1000 mg/m³.
  • High-humidity gases can be measured by special air purge. (VIEW370/VIEW370 PLUS)
  • Support for 16-channel sensor (VIEW370 PLUS)
  • It can be connected with our different models using a common path. (VIEW370 PLUS)
  • Dust

Operating Principles

The charge transfer of fine particles such as dust flowing across a pipe or airflue is applied to static induction and detected by the noncontact sensor. This signal is measured and converted into an alternating-current response. The friction current produced when particles directly hit the probe is cut and this realizes stable output through the special circuit.

Standard Specification
Model VIEW370/370PLUS Sensor
Housing Material ADC(epoxy coated)
Enclosure Rating IP65
Temperature Ambient Temp:-25℃~+55℃
Temperature inside the exhaust gas pipe.:
-25℃~+250℃(Standard)
-25℃~+400℃(Heat resistant model for middle high temperature)
-25℃~+800(Heat resistant model for high temperature)
Probe Length Max.1500mm
※Consult us for the length over 1500mm.
Probe Material 316SS・Teflon(Option:Teflon coating)
Process Connection Over R1・1/2
Cable 4-wire Shield Cable 0.5sq 50Ω/km
(max.1000m Single rayout)
Model VIEW370
Interface Module
VIEW370 PLUS
Multi-Controller
Power Source 90~260VAC 1A(50/60Hz) 90~260VAC 1A(50/60Hz)
Outputs DC4~20mA
(isolated, resistance load max.500Ω)
Serial RS232C・RS485
Relay contact 1cX2(AC250V 2A)
DC4~20mA
(isolated, resistance load max.500Ω)
Serial RS232C・RS485
Relay contact 1cX4(AC250V 2A)
Inputs 4 digital inputs
Sensor connection point 1 1-16
Resolution < 0.01mg < 0.01mg
Self-checks Communication
probe insulation
Zero and Span checks
Communication
probe insulation
Zero and Span checks
Memory capacity (1 Sensor)
Short:7 days @ 1 minute
Pulse data:2 hours @ 1 second
Alarms:500 entries
(4 Sensor)
Short:7 days @ 1 minute
Pulse data:2 hours @ 1 second
Alarms:500 entries
Housing Material ADC(epoxy coated) ADC(epoxy coated)
Enclosure Rating IP65 IP65
Display LCD
(Bar-graph,Values,Trend screen etc)
LCD
(Bar-graph,Values,Trend screen etc)
Temperature -25℃~+55℃ -25℃~+55℃
Product LineupWhen it's clicked, you can see details.

In addition to the above, various specifications are available.
For more information, see respective catalogs or contact us by phone or mail.

  • VIEW370Standard Type

  • VIEW370PLUSMultiController Type

  • Leak Alart73Controller-integrated Type

  • Leak Alart65-02Controller-separated Type

  • VIEW Ex800ATEX Intrinsically Safe Type

VIEW370
Standard Type

Absolute particulate emission concentration monitoring for environmental protection
Suitable for function monitoring of bug filter, cyclone etc.
Custom made sensor for any application.

VIEW370PLUS
MultiController Type

Absolute particulate emission concentration monitoring for environmental protection
Suitable for function monitoring of bug filter, cyclone etc.
Max. 16pcs of sensors can be connected to a controller.
Custom made sensor for any application.

Leak Alart73
Controller-integrated Type

Relative particulate emission concetration monitoring to see the change of the dust concentration in the exhaust gas comparing to the reference value which is already set.
Suitable for function monitoring of bug filter, cyclone etc.
Custom made sensor for any application.

Leak Alart65-02
Controller-separated Type

Relative particulate emission concetration monitoring to see the change of the dust concentration in the exhaust gas comparing to the reference value which is already set.
Separated controller model is useful at site.
Suitable for function monitoring of bug filter, cyclone etc.
Custom made sensor for any application.

VIEW Ex800
ATEX Intrinsically Safe Type

Intrinsic safety model accordign to ATEX directive.
Applicable to gas zone 0, 1 and 2 and dust zone 20, 21 and 22.
Max. 16pcs of sensors can be connected to VIEW Ex800PLUS.