O2 IN-Situ Analyzer OXITEC Series

Features

The gas sealed cell is produced by a special sealing technology!
High precision, high stability, and long life duration are ensured!

  • Automatic startup
  • Packaged with installation accessories and cable.
  • Functions are kept by the minimum maintenance.
  • Components can be replaced by the customer.
  • Gas sampling and processing are not needed.
  • Suitable for application under high temperature conditions (max. 1400°C)
  • Gas

Operating Principles

The oxygen concentration in a gas is measured from the difference in the oxygen partial pressure (pressure that oxygen accounts for in the atmospheric pressure) between the reference gas in the meter body and the measured gas.

Standard Specification
Model OXITEC5000/OXITEC5000 Ex Electronic Unit
Display LCD・LED
Indication System error,maintenance
Measuring Range 2 measuring ranges,0-99% adjustable
Power Source 115~230VAC 50/60Hz
Power Consumption 100-200VA(400VA at start-up)
Output 0/4-20mA max.500Ω resistance load
Relay contact System error,maintenance
Upper limit,Lower limit
RS232C,RS485,bus compatible
Contact capacity 230VAC 5A Resistance load
Temperature -20~+55℃
Enclosure Rating IP66
Model OXITEC5000 Sensor OXITEC5000 Ex Sensor
Sensitivity Below 1ppm O2 Below 1ppm O2
Accuracy ±0.2%(from measured value) ±0.2%(from measured value)
Allowable Pressure -50~+4000mbar -50~+4000mbar
Velocity 0~50m/sec 0~50m/sec
Allowable Temperature Around:-40~+80℃
Temperature inside the exhaust gas pipe.:
Max.600℃(Standard)
Max.1000℃(Heat resistant model for middle high temperature)
Max.1400℃(Heat resistant model for high temperature)
Around:-40~+80℃
Temperature inside the exhaust gas pipe.:
Max.500℃(Standard)
Max.1400℃(Heat resistant model for high temperature)
Enclosure Rating IP65 IP65
Probr Material 316SS
Option:Hastelloy、V4A、Incoloy、Protec
316SS
Option:Hastelloy、V4A、Incoloy、Protec
Responsiveness 0.5sec(about Velocity:10m/sec) 0.5sec(about Velocity:10m/sec)
Cable length Max.150m Max.150m
Product LineupWhen it's clicked, you can see details.

In addition to the above, various specifications are available.
For more information, see respective catalogs or contact us by phone or mail.

  • OXITEC5000Standard Type

  • OXITEC5000 ExATEX Intrinsically Safe Type

OXITEC5000
Standard Type

Gas temperature Max. 1400℃ analyzable.
Probe and filter materials are selectable based on each application.
Probe lengthes are selectable from some variations.

OXITEC5000 Ex
ATEX Intrinsically Safe Type

Applicable to gas explosion zone 1/2.
Gas temperature Max. 1400℃ analyzable.
Probe and filter materials are selectable based on each application.
Probe lengthes are selectable from some variations.